Mazak alarm 21 insufficient voltage. Mazak Alarm 394 ATC CONTROLLER MALF.

Mazak G code list for cnc machinists who work on Mazak INTEGREX 300/400-III/III T/IIIS/IIIST cnc machines. (M-SP ROT. Similar Threads: Mazak MYSTERY. Electron Z32 Alarms Complete list of Z32 CNC alarm codes. We just acquired a Mazak QT250-HP with the Mazatrol 640-T. Mar 21, 2023; Mazak; Replies 2 Views 187. I have alarm code 20 NMI Emergency Stop and code 202 Hydraulic Pressure down. Dec 16, 2001 · Our "new" (Slightly used) Mazak Quick Turn 8 has an alarm #23 - backup battery low voltage. Once on one of my T2 QT15's, I had the thermal trip INSIDE of the main transformer go bad, and gave me the 200 alarm. (Design the machine so that personal safety can be ensured even if the machine starts suddenly. When the control axis is removed, this alarm can be reset with the NC RESET button. Mazak has you covered from day one, and we're with you every step of the way to ensure your success. Nov 6, 2009 · Has any one had this problem, Went to fire up the Nexus 410A-II when these two alarms pop up #212 Magazine Drum Malfunction & #302 ATC Arm Driver Malfunction X & Y will home out Z will not Machine is not abused and has very little run time, last program run, drilling and tapping 4 holes caused the power supply voltage to dro at start. The tailstock has moved during spindle rotat Mazak Alarm 394 ATC CONTROLLER MALF. You can configure the alarm clock appearance (text color, type, and size), and these settings will be saved; they will be used when you open your web Alarm deactivation Explanation Alarm reset 1. Oct 17, 2015 · Now, whether it is in manual mode or automatic mode, the I get the '39 over amperage' alarm when the spindle starts to ask for power. Communication RD Battery Change Jul 22, 2010 · More than 21. I have opened the mr-j2-ct software and uploaded the back up, after turning back on I have tried to repair the absolute position with no success, I am unable to reset the two alarms 1. Jan 10, 2009 · Mazak alarm 52 battery alarm will not reset after battery replacement. Thread starter RobertBarnhart; Start date Apr 27, 2015; Replies 4 Views 9,386 R. EYE EXT. Mazak Alarm 321 MODE CHANGE IMPOSSIBLE (DURING ATC CYCLE) Dec 30, 2010 · When an alarm occurs, always eliminate the cause of the alarm and ensure safe operation before resetting. I have it powered up and moving around, I can jog my spindle, but when I try to turn the spindle on or do anything involving the 'start' button in automatic mode (even with the door closed and interlock in place), I get an alarm 350 'Operating Switch Fault' which causes an E-stop condition. Spindle drive is Frequol make. Low voltage encoder backup data, Battery is ok! 2. View Profile Check the servo power supply for voltage into and out of. ) Feb 18, 2022 · Hi, I'm just getting into some Mazak gear for the first time. They will not reset. - Reduce the reference position return speed. MPower gives you single-source access to end-to-end support for the lifetime of every Mazak machine. Follow the instructions to successfully change these batteries. 1156 MCS DC-bus voltage alarm; 1735 Sub-spindle chuck pressure insufficient; Alarm List for the Mazak INTEGREX 300/400-II For other Mazak alarm lists visit Apr 28, 2005 · I have a 350 alarm and if I try the reset button and button below the reset button and I will then get alarms 204, 21 and 33. I've attached a picture of the diagnostic page with the alarm. Description A TOOL EYE extend/retract command has been given with the SET UP switch remaining set to “O” and the front door remaining open. Mazak Alarm 324 DIFF. Main PLC card rack has no red led's lit while all green led's are lit according to the manual. I Alarms 1. Never go near the machine after restoring the power after a failure, as the machine could start suddenly. 5 Faulty parts in the servo amplifier Change the amplifier. Check and remedy Carry out the zero-point return operation. Jul 22, 2010 · 10. Speculating if the not on tension bearings have come loose May 7, 2011 · On my mills, it's about a 20-30 second delay before the alarm appears. Nov 22, 2021 · 96 QT30 T-plus here. I have replaced both the MDS-A-SP-260 spindle drive and the MDS-A-CV-260 converter drives (with good known) units to no avail. M01 Some ax does not pass Z There are two different types of batteries—backup batteries for encoders and relocation batteries—that need to be replaced every 2,000 hours or when warning alarms appear. I am new to this machine. Jan 28, 2015 · I am using Mazak Quickturn 20 machine, machine is giving alarm - Alarm 21 Driver Unit Power Mulfunction Machine is normally working when started by spindle manually and on 300 rpm or higher, but when working when I stop the machine on 300 rpm or 800 rpm and then I start the machine again and it gives alarm 21. Feb 11, 2015 · I have had an alarm on my MAZAK quick turn NEXUS 100-II MSY, which is a red alarm 175 (Description: Table unbalance check N/A) and after switching on and off again a red alarm 21 (Description: System error). Check and remedy Open the Contact Mazak Technical Center or Technology Center. Thanks, Bob Instruction Manual and User Guide for Mazak Alarm 10 Detector Malfunction. Description Although a spindle orientation command is given, the orientation confirmation signal does not turn on within a predetermined time. ) displayed in parentheses. Once the alarm appears, I have to power off the control to clear it. Description An alarm signal has been received from the ATC amplifier. Relocation Detected R. Description The inside/outside chucking selection is performed with the chuck not opened. Mazak Alarm 253 OVERLOAD DETECTION Sep 27, 2018 · Tried to replace mitsubishi AC motor but spindle still wont orient. Even Mazak support couldn't tell me. Failure to observe this item could lead to ruptures or damage, etc. The X and Y axis move fine, but the Z sounds like it is shuttering and then it will thrown the servo overload alarm. ) Description The automatic operation mode was selected without carrying out the zero-point return operation after the power supply had been turned on. Check and remedy Change the setting of the SET UP switch to “I”. Discover More Tips. Cycling the power Turning the power off and then turning it on again. Do you guys know how to clear these alarms and get the machine back and run? Thanks FstopView attachment 341899 Feb 4, 2014 · Hello, I'm running a Mazak 640M Fusion CNC Mill. Sep 14, 2008 · Hi, I've bought a old Mazak VQC 20/50B with Mazatrol M1 Controller with pallet changer. Turning on RES (Reset) with input device 2. Power down and up again to clear battery voltage 0 alarm. If the alarm occurs immediately after power on when a cable or encoder was disconnected from the battery. When I powered it up and tried to clear alarms so I could move the axis. The spindle may start up fine and run for a few minutes and then alarm out. Mazak Alarm 361 TAIL ALARM Description The tailstock amplifier has detected an overload or too great an error. Joined Dec 4, 2014. Within 30 seconds, the machine trips again and get the same 201 break trip alarm on the T32. There should be a warring diagram on the motor or inside the cover. Ours would throw the #8 battery alarm and it would always be the C/D cell looking battery on the memory unit below the axis drives. Mar 12, 2013 · Check the voltage at the PP and the disconnect on the wall and at the machine 244V on all legs. Also as you can see there is several other alarms listed but no explanations. Also the X & B drive unit is flashing F4 and F1 usually its just a static 56 showing on the display. This alarm can also be reset with the PR and AR resetting conditions. IMP. We cut the drill bit and broke it off to make sure the spindle was loose. Mazak Optonics believes one size does not fit all when it comes to 2D laser-cutting technology. If I realize my mistake fast enough, I can jump into MDI and command another tool change before the alarm appears. Checked all low voltage supplies and all appeared correct. Does anyone know where the battery is located? We looked around in the back, but couldn't find it. 工作機械による生産活動のイノベーション。それを支えるのがマザックの最先端テクノロジーです。マザックの工作機械は5軸・複合加工機による工程集約、さらにギア加工、研削、レーザ加工などの機能を付加することで進化を続けています。 May 13, 2011 · On my mills, it's about a 20-30 second delay before the alarm appears. Description An overload has been detected in a machine having an overload detection option. More than 21. We would have to cycle the power every morning and the alarm would clear. Do not mistake the terminal connections. We replaced it with a new one and hoped it will solve the problem. Please see attachment for the alarm. both are refurbished. Mazak Alarm 270 SPINDLE ORIENT EXCEED TIME. The Position page only shows one alarm, Diagnostics will show them all, if you have other alarms. Jun 29, 2011 · I turn on the machine and i have a bunch of alarms, and machine when to alarm 15 - system malfunction. ) Nov 6, 2013 · I have a couple alarms 2 emergency stop 10 detector malfunction how can I clear these alarms? machine is a 510c-ii. We checked the voltage across and found it had dropped to . If I switch off the 100 amp breaker to the VFD, I get alarm 204 spindle drive alarm along with the 205 alarm. Voltage to machine is right at about 200V and DC bus voltage is 287V. Feb 22, 2005 · Hi all; Having problems with x+,x-,y+,y- overtravel alarms on my quickturn 20 with mazatrol t1. E7 & the spindle is not rotating. But if there is an alarm on the spindle drive then its probably Nov 19, 2009 · Error 21 is a software alarm and it may be because one or more of your MR-J2s lost its mind. I checked all the breakers and non of them tripped. Got the power hooked up to it today had to rewire transformer to take 480 since last shop had it wired for 230. Any insight on probable causes/ solutions? Thanks. For alarm messages example 10 Detector Malfunction 1 (&00000001,&0007) I read the alarm as number 1 on the drive, and axis number 7 2. This will either be the result of something wrong with the voltage source (broken wire, poor connection, or an actual power problem) or something wrong internally to the power supply unit. Any advise on this would be much appreciated. Mazak Alarm 267 BALL SCREW X44C (Fanuc 21 Model B) Fanuc 21 Alarm Codes 0 PLEASE TURN OFF POWER 1 TH PARITY ALARM 2 TV PARITY ALARM 3 TOO MANY… Mitsubishi G Codes – CNC Lathe 700/70 Series Mitsubishi G Codes for CNC Lathe machines with Mitsubishi CNC controls (Mitsubishi 700/70 Series). After å while alarm 242 spindel orientation malfunction. Description An alarm signal has been sent from the shifter-use amplifier to the NC unit. A spindle rotation command was given during mis-chucking. PR: Reset by turning the NC power ON again. 000 machines ; Just wondering how i can clear alarm code 1224 on Mazak Matrix Control? 07-23-2010, 04:35 PM #2. (APC)=Absolute pulse coder. It is recommended to add a high-voltage insulating sleeve over the high-voltage wire. After this time, errors began to appear sporadically. When you try to do a spindle orient I get this alarm 281 no spdl orient (special tool) any help would be greatly appreciated. If they drain quickly you must determine which pulse coder or cable is shorted and drawing the battery down. 1393 1394 1395 1397 1396 Alarm message R. Mazak’s 2D laser machines are available in two configurations, depending on the needs of the laser-cutting application. Mar 21, 2023; Mazak; Replies 2 Views 363. HV Excessive voltage alarm LV5V +5V of control power is abnormally low. Cut off the main circuit power with the contactor when an alarm or emergency stop occurs. 8. Jul 3, 2009 · I have a vtc20 with mazatrol M plus control. Check backup battery for proper voltage; Reset absolute positioning according to machine and drive manuals; Check feedback for connection issues or problems with functionality; S3 10: Under Voltage: Check incoming 3 phase voltage; Voltage should be properly rated and balanced within 5% of each other; Check connections Jul 8, 2022 · Please help me i work with a mazak vtc 20 b and when i try to start spindle it show me a alarm "M41 SPINDLE MALFUNCTION 1 " the spindle drive show it "F4 32" The machine opening normal and it going to home position normally the problem occurs when i try to start spindle if anyone can help Mazak Alarm 250 SPINDLE START MISOPERATION. To change the mode, wait until ATC has been completed. ) Description A milling head unclamping command has been given during rotation of the milling spindle motor. Aug 5, 2016 · We are having intermittent problems with our QT20, alarm 15 system malfunction. Or, it may alarm out as soon as I hit go. Thread starter Jvanman; Start date Jul 12, 2019; Replies 4 Views 8,479 J. Also this a Japan imported machine so we run a large voltage transformer to bring the voltage down. 251 (Spindle Driver not functional). Or close the front door. Check and remedy After the milling spindle motor has stopped, perform the operations described at left. Refer to the Mazak Manuals for detailed information on specific alarm codes; Identify the recommended troubleshooting steps and follow them carefully; Tip 2: Regular Maintenance. ) 21 SYSTEM ERROR. Yes, friend's machine was sitting in his hot garage for 2 years. Post troubleshooting recommendations Feb 11, 2015 · I have had an alarm on my MAZAK quick turn NEXUS 100-II MSY, which is a red alarm 175 (Description: Table unbalance check N/A) and after switching on and off again a red alarm 21 (Description: System error). Sign up for technical training, access phone support, order parts, track a spindle rebuild and so much more. Take a snap of the inside of the electrical box on the back of the machine. You can check the voltage back at that contactor inside the cabinet w/o having to take apart any of the connections to make sure the wiring and the voltage agree. 03-31-2009, 10:33 AM #8. Swapped power supply unit from HD2 to HD1 with no change in behavior. Check and remedy Check the lubrication oil level, and replenish lubricating oil if required. Lee. Therefore, Mazak offers a wide range of 2D laser machines designed to meet the specific needs of a fabricator’s operation. the servo still shows the same alarm. 6V battery. In the spindle drive the display shows no. Apr 27, 2015 · Mazak alarms. I cant get a hold of my night shift to find out what happened. Mar 28, 2009 · More than 21. Jvanman May 21, 2020. HOW do you clear this ANNOYING Mazak alarm??!!! NOBODY KNOWS!! Need Help!-Mazak QT-10 T2 manuals --acct w/ mazak? Could pull the cover off the motor and see which wires are tangled together. May 2, 2023 · Troubleshooting Tips for Mazatrol 640M Alarms Tip 1: Consult the Mazak Manuals. Operation Alarms (M) M01 Dog overrun 0001 Details When returning to the reference position, the near-point detection limit switch did not stop over the dog, but overran the dog. Troubleshooting 2011 Integrex Tool Change Failure (NEED HELP) Thread starter Pistonring12; Start date Mar 2, 2023 - 1295 Tool Missclamp sensor alarm Nov 2, 2018 · Alarm 67 is indicating that the MDS-A/B/C-CV power supply unit has detected that either the R, S, or T line of the AC 200V has lost power, or is not connected. 000 machines Check the servo power supply for voltage into and out of. Action Contact Mazak Technical Center or Technology Center with the information of the numbers (Alarm No. Checking method Alarm occurs if g»ver is switched on after disconneŒ:tn of all cables but the Oct 2, 2019 · Hi, I have problem with my Mazak QuickTurn 15N (1990y T32-2) I had a problem with the main power supply in the building (blown fuses during machine start). We found a 3. Pushing the "SET" button while the display of the servo amplifier is the current alarm display status 3. 22 AMPLIFIER NOT EQUIPPED. The float switch (SL1) has turned off. Still giving overload. View Profile View Forum Posts Private Message View Gallery Uploads Registered Drives alarm with only the main breaker turned on (not control on)- all drives if Fanuc should have dash. I'm running a Mazak 640M Fusion CNC Mill. Oct 22, 2020 · Hi All, Does Anyone know how to reset this alarm on a Mazak VCN-510C-II? Thanks in advance. At that time, you may be asked whether and how the machine was relocated. FJV-60/80. 7. Oct 11, 2012 · 16/18/21, 16i/18i/21i, 160i/180i/210i, 0/00/0-mate, 0i Power down and up again to clear battery voltage 0 alarm. Lee i have a mazak m-plus cnc that bring the alarm "31 servo malfunction 1 The alarm message will appear, and the preselected sound will be played at the set time. I am facing a problem with Machine the Spindle is not functioning it shows Alarm No. Advertisement. Mazak’s QUICK TURN 350 CNC Turning Center delivers great value as part of the manufacturing industry's widest range of Multi-Tasking machines. Operation Alarms (M) I - 1 1. Aug 18, 2023 · 6. We had a power failure because of lightning, ever since we have this alarm. Aug 24, 2018 · I am new to the machine I am running a MAZAK BARTAC (sorry for the caps my iPhone is dumb) i100s. (Excluding alarms 32 and 37. 2. Check and remedy Check the overload detection level. i have a mazak m-plus cnc that bring the alarm "31 servo malfunction 1 Jul 30, 2019 · For additional assistance please contact the Mazak Laser Applications Department at: 1-888-MAZAK US. 000 machines It has a 260 slideway lube alarm it's getting plenty of lube so I assume Nov 5, 2016 · Well I finally have my new to me 1989 Mazak QT-15 set in place. 13. Today it popped alarm 15 during a run and during a few power shutdowns and restarts it kept coming back. the new spindle amp is flashing F6 and 23. D. Machine was sitting idle when 4 alarms popped up. Cutting graphic size too large or too small? Check if the output graphic size is consistent, if there are changes in the Z-axis height position, and if calibration files need adjustments. Alarm 15, drive 1 =A6, drive 2 =f6/e7, drive 3=e6. caused the power supply voltage to dro at start. and Sub No. Mar Mazak Alarm 325 TL. About Mazak Optonics Corporation. If the alarm is not cleared, please contact your MAZAK service representative. :( The problem was in one of the MR-J2 drives, Someone changed a switch that is on the front of the drive, The LED screen in the front of the drive has to digitals numbers and on the right side has a switch with numbers (0 to 10) and letters (A to F), I have four drives and none of the drives can't have the same number, so two drives were using the same number(2), I have to go to the MR-J2 and Mazak Alarm 320 TOOL UNCLAMP IMP. . Check and remedy After turning NC power off, turn off the main circuit breaker and then turn if back on. Or Reduce the cutting load. Replaced batteries, reloaded parameters via keypad, and cleared all but this one fault code. Live and learn. I thought it was the fault of the spindle controller (Mitsubishi Freqrol FR-SE) Oct 3, 2016 · So arrived at the shop this morning and am having a closer look in the cabinet of this Mazak SQT10MS. If any drives have alarm then the odds are that it is internal in the drive. RobertBarnhart Plastic. I do M19 and spindle spinns up rpm but never completes orient. Description The pressure switch (SP7) for ball screw and C-axis gear lubrication does not turn on or off within a fixed time. Dec 22, 2011 · I've talked to Mazak and Mitsubishi by phone and due to the age of the machine there's not much they can do. etc. Perform routine maintenance on your Mazak machine to prevent alarm occurrences Fanuc 10/11/12 Alarms Fanuc Series 15 Alarms Fanuc 15i Alarms Fanuc 16i 18i Alarms Fanuc 21 Alarms Fanuc 21i Alarms Fanuc Alarms Fanuc Spindle Alarms Fanuc 6M 6T Alarms D. Checking method Alarm occurs if g»ver is switched on after disconneŒ:tn of all cables but the Mazak alarm cancel. Mazak G Codes G Code Function G00 Positioning G01 Linear interpolation G01. Check and remedy After turning NC power off, turn the main circuit breaker off and then turn it back on. 3. Injury prevention Do not apply a voltage other than that specified in th is manual, on each terminal. Mazak VTC-300C Alarm 202; problems MAHO 300c 1984; 11-28-2007, 12:06 PM #2. DC voltage for driving main circuit is considerabley high. Remedy - Increase the length of the near-point dog. Close the chuck and start operation with the workpiece gripped. High-precision, high-productivity, double-column vertical machining center Jan 16, 2006 · Make sure you go to the Diagnostics page, to see if there is more than this alarm. Everything comes up, as well as the control. Once the power leaves the disconnect at the machine it routes to the MC boards and not so easy to check. We just wired the machine up and were trying to get it going. DC link voltage low alarm Regenerative discharge energy in short time is large or regenerative discharge circuit is faulty. Power was mstored after the bus voltage had dropped to 2DDVDC. Ryan. Replace SPM Alarm Code 07 Excessive Speed Incorrect speed detector parameter setting Alarm Code 09 SPM overload/ overheat Check SPM internal and external cooling fan Send in SPM to us for wash & test service Alarm Code 11 Over-voltage in DC link section Faulty incoming power or PSM Alarm Code 12 Over-current in Mazak Alarm 21 Insufficient Voltage In addition to different barrier options, there are several different ways to use security gates for access control. Control power low alarm LVDC DC voltage for main circuit is extremely low. After power on of the control If all drives ready up except the spindle drives this is normal. We make systems that continue to operate well over a long life. 1 Threading with… After the system boots, the following alarm appears: “22 Feedback System Malfunction (5,0,&0025)” According to the manual for Alarm 22 ( , , 25): Cause - This alarm implies decreases in the voltage of the backup battery for the absolute position data detection circuit of the control card. Click "Occurred Alarm Reset" in the "Alarm Display" window of MR Configurator2. We have 1 Mazak Alarm 10 Detector Malfunction manuals for free PDF download. 12. Oct 11, 2012 · We have a mazak Slant Turn 60N and we have been experiencing the same alarm on our machine, alarm "main supply power malfunction". 7. Nov 3, 2021 · It's probably not in there, if it is the one behind the control it's likely on the board on the back of the monitor. In the back panel both MR-J2's are flashing AL 02 51 36 91 4C. Can anyone point me in the right direction? My Nov 5, 2009 · This is on a Mazak QT-20 with a Mazatrol T-Plus controller. High-voltage wire arcing? This issue can be quite troublesome. Oct 19, 2021 #3 I am using Mazak Quickturn 20 machine, machine is giving alarm - Alarm 21 Driver Unit Power Mulfunction Machine is normally working when started by spindle manually and on 300 rpm or higher, but when working when I stop the machine on 300 rpm or 800 rpm and then I start the machine again and it gives alarm 21. ) Check and remedy 1. 11. Help Others. Apr 27, 2015 #1 Alarm Code 03 DC Link fuse blown. I'd reload the MR-J2 parameters like onthebumper mentioned. Purchase replacement batteries from Mazak Technical Center or Technology Center and replace the batteries with new ones. psychomill. Mazak Alarm 329 CHUCKING SELECTION PROHIBITED. Or Dec 16, 2014 · We replaced the main power supply and the spindle amplifier (which I assume is the drive unit) not sure though. Mazak Optonics Corporation is a major supplier of laser-cutting systems, offering 50 laser models and leading the industry in the implementation of emerging laser technologies. Cause Amplifier power is not yet turned on. . Mazak Alarm 270 SPINDLE ORIENT EXCEED TIME Mar 2, 2023 · Mazak . I’ve been running multus for years and this is completely new to me. Mar 20, 2023 · Open the ALARM screen; Press the RESET key on the NC unit; After pressing the RESET key, check to make sure that the alarms 5002, 5102, 5202, 5302, and 5602 are not displayed; If the alarms are present after completing the steps outlined above, try the battery replacement procedure again without turning off the main power breaker. Log in Register. It alarmed out yesterday for an alarm 291 no tool unload, tool in magazine. Check and remedy The operation mode cannot be changed during ATC. Cause Trouble has occurred during communication with the amplifiers or during communication data processing. (Main circuit g»ver switched on within 5s after it had switched off. (Chuck sensor provided. MODE (ORIGIN RET UNFIN. Check and remedy The spindle motor detector/controller is abnormal. Loosed and tightened those connections as well. Mazak Alarm 253 OVERLOAD DETECTION. this is the alarm on mazatrol controller 21 Drive unit power malfunction 1,0,&0023 alarm. DCSW Abnormal regen- Mazak Alarm 321 MODE CHANGE IMPOSSIBLE (DURING ATC CYCLE) Description Mode changing has been attempted during the ATC cycle. This alarm can also be reset with the AR resetting conditions. Mazak has palmed us off to Mitsubishi and the engineer is here now but seems to be at a loose end . When setting the alarm, you can click the "Test" button to preview the alert and check the sound volume. It will even alarm out in manual mode when I have the RPM of the spindle at '0'. Right in front of my face, there is a breaker tripped # QFB11 So, I reset it and fire up the machine. Oct 31, 2010 · Phase light was off when the Mazak tech showed it to me. absolute position data disappeared. 4. Thread starter countryboy1966; Start date Mar 20, 2019; Replies 4 Views 14,204 C. Mazak ATC Alarm 212 & 300. This is probably basic knowledge but for some reason I'm having trouble finding a definitive answer. This morning when I came in I noticed it had "Alarm 21 System Error" up on the screen. Cancel any alarm for Mazak machine Apr 12, 2005 · We twisted the drill bit with pliers and it was loose, still throwing servo overload alarm when we tried to raise the spindle. 77 likes · 1 talking about this. Mar Mar 23, 2006 · We checked the panel at the back and found that one of the servo drives was giving an ALARM "AL-01-21" alternately blinking. Talking to Mazak the thought was to clear the 208 alarm first which may clear the other alarms Mazak Alarm 324 DIFF. Mazak Alarm 325 TL. Mazak Alarm 394 ATC CONTROLLER MALF. Mazak Alarm 366 SHIFTER CONTROLER MALFUNCTION. Can read rpms so i guess plg sensor is ok. Mazak Alarm 267 BALL SCREW X44C LUBRICATION ALARM. Description 1. What machine is this? and how did this all originally start? Feb 4, 2014 · Mazak Alarm 21 System Error. ls lc pz zr bw hd sn be og gr